Mill direct · Tianjin, China · EN 10219 tube · ISO 1461 galvanising on request Seller of record: XinYonSen +86 150 2264 1456 2268199197@qq.com
Steel frame millTianjin, China · mill direct
RFQ

SYSTEMS 00 · INDEX

Six house types, and the decisions that change the frame in each.

A system page is not a catalogue of buildings. It is the list of choices that change the steel: span, bay, eaves height, arch or truss, covering, vent pattern. Each type below carries reference configurations we quote regularly, with the load caveat attached.

Multi-span house with side-wall fans — XinYonSen
Multi-span house with side-wall fansProject photo

The frame is the same mill product in every type. What changes is how the members are arranged, how the covering is fixed, and which loads the arrangement has to carry. That is why we quote a house as a system and a tube as a product.

01

Multi-span film house

6.2–12 m bays, gutter-connected, film roof. The default for commercial vegetables.

3 configurationsMulti-span film house
02

Single-span tunnel

6.2–8.5 m arches, no gutter, lowest steel per m². Season extension and berries.

2 configurationsSingle-span tunnel
03

Venlo glasshouse

9.6–12.8 m spans, glass, high light transmission, long service life.

2 configurationsVenlo glasshouse
04

Sawtooth PC house

9.6 m sawtooth with polycarbonate, for high light and snow shedding.

1 configurationSawtooth PC house
05

High tunnel & shade

4.2–6 m bows, roll-up sides, shade net. Low capital, fast payback.

2 configurationsHigh tunnel & shade
06

Hydroponic & gutter

NFT channels, benches and gutter lines for leafy crops and strawberries.

1 configurationHydroponic & gutter

The five decisions that change the price

Decision, effect on the frame, and who should make it
DecisionWhat it changesWho decides
SpanArch section and wall, gutter section, post sizeYour engineer, with the crop and machinery
BayPurlin count, truss or arch count, gutter lengthYour engineer
Eaves heightPost length, bracing, internal volume, labourGrower + engineer
CoveringPurlin spacing, clips, vent hardware, roof pitchGrower
Load caseEverything above, plus anchorsEngineer, to the local code

We quote against these five; we do not choose them for you. If one is missing we will say which one and why it matters.

What “reference configuration” means here

A reference configuration is a house shape we have quoted before and can price quickly. It is not a structural design and it does not carry a conformity certificate. The design responsibility stays with your engineer or house designer.

NEXT STEP

Send your plot size and load case

Width, length, eaves height, snow and wind figures are enough to come back with a frame schedule and a covering list. No drawing needed on the first round.